Energy Services & Repair Division

M&M Tanks’ Energy Services & Repair Division specializes in the erection/repair/demolition of API 650 and AWWA D-100 welded steel tanks. We perform API 653 tank repair and ASME IX/API 1104 fuel line work, plus associated civil site work and underground utilities relocation.

M&M delivers on-time quality turnkey construction at fair prices to our clients in Hawaii and throughout the Pacific Island Nations.  In addition, we are available for marine and transportation repair services.

M&M’s welding team brings certified API/ABS/AWS experience and quality to each jobsite. Safety First and planning define M&M’s approach. Customer satisfaction and building excellent client relationships are our #1 priority. Our centrally located base yard in Honolulu ensures timely project completion in Hawaii and throughout the Pacific Island Nations.

   
   
 
  
 
   
   
   
   
   
   
   
 

Owner and Location:

Hawaiian Electric Company, Kahe, Oahu, Hawaii

Type of Contract, Amount, & Date:

Prime, $609,606, 2003

Project:

Kahe Fire Water Storage Tank

Description:

Erect and coat 350,000 gallon welded steel water tank for fire control and water lines connecting to existing fire fighting system.

Contact Person:

Jon Yanagida, Project Engineer, HECO, 808-543-7005
Project Manager: Michael J. Deegan
 
 

   
 
   
 

Owner and Location:

US Army; Kwajalein Range Facility, Republic of the Marshall Islands

Type of Contract, Amount, & Date:

Subcontractor, $1.2M, 2006-2007

Project:

Repair of Fuel Farm, FAC 965 and 1153

Description:

 

Comprehensive API 653 repair of 7 fuel storage tanks in the Kwajalein Range Facility tank farm. Work included tank bottom replacements and roof repairs. Corroded piping and valving were repaired in compliance with API 1104.

Contact Person:

Andrew Beall, Mechanical Engineer, Kwajalein Range Facility. (805) 355-4956
Project Superintendent: Denver Webb
 
 

 
 
 
 

Owner and Location:

Aircraft Service International Group (ASIG), Sand Island Bulk Storage

Type of Contract, Amount, & Date:

Prime, $38,366, March/October 2007

Project:

API 653 Repairs of Jet A Tanks #06 & #11.
Note: M&M Tanks, Inc. provides regular maintenance services to ASIG Bulk Storage Fuel Facility.

Description:

Tank Bottom Repair Tanks A and #11, Sand Island Bulk Storage Fuel Facility.

Contact Person:

Benjamin Chun, Maintenance Supervisor 808-836-1830

 
 

 
 
 
 
 

Owner and Location:

Pearl Harbor Naval Shipyard, Pearl Harbor, HI

Type of Contract, Amount, & Date:

Subcontractor, $985,000, 2005-2006

Project:

Inspection and Repair of Red Hill 32” Fuel Line

Description:

 

API 1104 fabrication and installation of 32” diameter pig launcher/receiver in Pear Harbor’s main fuel line. Performance of a “smart pig” inspection and re-commissioning of the fuel line.

Contact Person:

Herb Kikuchi, Head of Operations, PHNS, 808- 473-7805

Project Superintendent: Michael J. Deegan
 
 

 
 
 
 

Owner and Location:

AFCEE, Red Hill Tunnel Pearl Harbor Naval Base, Hawaii

Type of Contract, Amount, & Date:

Subcontractor, $822,000, 2007

Project:

Replace Elevator #72 @ Red Hill

Description:

WERC Task Order No. 253: Elevator 72; Structural Steel Component, Architectural Component, Mechanical Systems, Installations, Environmental Remediation & Demolition and Demolition of Mechanical Services.

Contact Person:

Lisa Williams, Senior Contracts Administrator 808-440-0262

Project Manager: Denver Webb
 
   

Copyright M&M Tanks 2008. All Rights Reserved.  Website by: ImprintWebDesign